CLS-Blocker

LAMILUX Translucent Façade and Roof

Flexible in design, colour and function


Benefits at a glance

Translucent Façade and Roof


Energy efficiency

  • Perfect thermal insulation with General Building Approval
  • Modular overall system consisting of numerous, perfectly coordinated and innovative single components
  • The interior and exterior metallic components in the supporting structure as well as in the flap systems are completely thermally separated from each other
  • Composite glazing with lowest heat transmission coefficient
  • All glazing variants achieve the highest airtightness class according to EN 12207 (up to class 4)

Stability, safety and SHEV

  • Effective ventilation effect with the Smoke Lift W | R (DIN EN 12101-2), as tandem-serial
  • Fast opening in the event of fire due to thermal triggering, thermal and CO2 remote triggering or electric remote triggering
  • All smoke and heat exhaust ventilation units can also be combined with ventilation systems
  • Highest stability of the flap systems in open position through spring-mounted multi-joint traverses
  • We provide professional, regular maintenance

Tested and certified

General Building Approval: German cross reference
General Building Approvals (ABZ) are issued by the German Institute of Building Technology (Deutsches Institut für Bautechnik – DIBt). This certificate verifies that a construction product meets the technical requirements for its use.

LAMILUX Quality Certificate – This certificate provides proof that our skylights are consistently manufactured and implemented in accordance with product approvals and the technical standards specified in the approvals. We keep our promises.

Test certificates and european technical approvals

  • Thermal protection properties tested in accordance with EN ISO 10077-1
  • Watertightness tested in accordance with EN 12208
  • Airtightness tested in accordance with EN 12207
  • Fire behaviour of the glazing classified according to EN 13501-1
  • Melt-out verified in accordance with DIN 18230-1
  • Single and double flap systems of the smoke and heat exhaust ventilation systems are tested and classified in accordance with EN 12101-2

Variants

Translucent Façade and Roof


Glazing types

Note: The Ug value is determined per DIN EN 673 (vertical installation). The profile structure's actual heat transmission values, including those of base profiles, gable wall profiles and flap profiles, are used to calculate the Continuous Rooflight's energy values (Uw). 

PC40-4

Ug –value (vertical | horizontal installation):1.5 W/(m²K) | 1.6 W/(m²K)
Sound insulation value according to manufacturer's information:20 dB
Maximum service temperature without load:-40° bis + 115 °C
UV resistance:Co-extruded, external UV protection layer
Hail resistance:Resistance class HW 5 (seal tightness)
Installed thickness | weight:40 mm | 4.00 kg/m²
Light transmittance (τ) (opal | clear):approx. 29% | approx. 66%
Total energy transmission (g) (opal | clear):approx. 42% | approx. 60% 

PC40-7

Ug value (vertical | horizontal installation):1.1 W/(m²K) | 1.2 W/(m²K)
Sound insulation value according to manufacturer's information:22 dB
Maximum service temperature without load: -40° bis + 115 °C
UV resistance:Co-extruded, external UV protection layer
Hail resistance:Resistance class HW 5 (seal tightness)
Installed thickness | weight:40 mm | 4.30 kg/m²
Light transmittance (τ) (opal | clear):approx. 25% | approx. 55%
Total energy transmission (g) (opal | clear):approx. 39% | approx. 56%

PC50-10

Ug value (vertical | horizontal installation):0.90 W/(m²K) | 0.92 W/(m²K)
Sound insulation value according to manufacturer's information:22 dB
Maximum service temperature without load:-40° bis + 115 °C
UV resistance:Co-extruded, external UV protection layer
Hail resistance:Resistance class HW 5 (seal tightness)
Installed thickness | weight:50 mm | 5.00 kg/m²
Light transmittance (τ) (opal | clear):approx. 21% | approx. 48%
Total energy transmission (g) (opal | clear):approx. 38% | approx. 50%

PC60-12

Ug value (vertical | horizontal installation):0.75 W/(m²K) | 0.77 W/(m²K)
Sound insulation value according to manufacturer's:22 dB
Maximum service temperature without load:-40° bis + 115 °C
UV resistance:Co-extruded, external UV protection layer
Hail resistance:Resistance class HW 5 (seal tightness)
Installed thickness | weight:60 mm | 5.80 kg/m²
Light transmittance (τ) (opal | clear):approx. 18% | approx. 42%
Total energy transmission (g) (opal | clear):approx. 34% | approx. 45%

Flap systems for shevs and ventilation

  • Integration as single flap or tandem serial single flap
  • Ventilation function triggered manually or control technology automated by electric motors (24 Volt/230 Volt) with spindle opener or pneumatic drive units with pneumatic cylinders
  • Fast opening in case of fire by thermal release, thermal and CO2 remote release or electric remote release
  • Energy-efficient control of flap systems for natural ventilation with wind and rain sensor set as well as additional control components
  • Optimum tightness against driving rain due to welded sealing frame
  • Optimum insulation effect

 

Sizes and value

Translucent Façade and Roof


Aerodynamically effective opening surface of the flap system
at 30° inclination of the glazing surfaces

Height (mm)Width (mm)    
 1000150020002100 TS*4200 TS*
8300,52 m²0,77 m²1,02 m²1,03 m²1,91 m²
11000,67 m²0,97 m²1,29 m²1,32 m²2,39 m²
14000,81 m²1,21 m²1,61 m²1,56 m²2,99 m²
16900,96 m²1,43 m²1,91 m²1,85 m²3,54 m²

* only as tandem serial smoke and heat exhaust device

Aerodynamically effective opening surface of the flap system
at 45° inclination of the glazing surfaces

Height (mm)Width (mm)    
 1000150020002100 TS*4200 TS*
8300,52 m²0,77 m²1,02 m²1,03 m²1,91 m²
11000,68 m²1,00 m²1,33 m²1,32 m²2,44 m²
14000,84 m²1,25 m²1,66 m²1,59 m²2,99 m²
16900,99 m²1,49 m²1,98 m²1,89 m²3,54 m²

* only as tandem serial smoke and heat exhaust device

Aerodynamically effective opening surface of the flap system
at 60° inclination of the glazing surfaces

Height (mm)Width (mm)    
 1000150020002100 TS*4200 TS*
8300,50 m²0,74 m²0,99 m²0,96 m²1,84 m²
11000,65 m²0,97 m²1,29 m²1,23 m²2,39 m²
14000,81 m²1,21 m²1,61 m²1,53 m²2,93 m²
16900,96 m²1,41 m²1,87 m²1,82 m²3,47 m²

* only as tandem serial smoke and heat exhaust device

Aerodynamically effective opening surface of the flap system
at 90° inclination of the glazing surfaces

Height (mm)Width (mm)    
 1000150020002100 TS*4200 TS*
8300,49 m²0,73 m²0,97 m²0,94 m²1,81 m²
11000,64 m²0,95 m²1,26 m²1,21 m²2,31 m²
14000,80 m²1,19 m²1,58 m²1,51 m²2,88 m²
16900,94 m²1,38 m²1,84 m²1,78 m²3,41 m²

* only as tandem serial smoke and heat exhaust device

Technical details

Translucent Façade and Roof


Tandem-serial flaps
ventilation with tandem-serial flap systems

Cutting-edge technology

LAMILUX solution: Ventilation flaps can be installed directly next to each other. 
More space for ventilation with the same Continuous Rooflight surface.

Tandem-serial SHEV flaps

Cutting-edge technology

LAMILUX’s own NSHEV tested according to DIN EN 12101-2: SHEV’s can be installed directly next to each other.
More space for smoke extraction with the same Continuous Rooflight surface.

TIP Technology

Downloads

Translucent Façade and Roof


Translucent Façade and Roof

Brochure

en-us-gb

Download collection

Download